1000 VA / 900 W, (PF): 0.9,Double-Conversion, Sine Wave, USB, Serial, RMCARD205, Relay, EPO, Black
- Capacity: 1000 VA / 900 W
- Power Factor (PF): 0.9
- Topology: Double-Conversion
- Waveform: Sine Wave
- Output: 100, 110, 115, 120, 125 V ± 2% (configurable)
- Plug type & cord: NEMA 5-15P, 10 ft. cord
- Outlet types: 8 × NEMA 5-15R
- Monitoring & Management: USB, Serial, RMCARD205, Relay, EPO
- Data line surge protection: Telephone, Network
- Management software: PowerPanel® Business Edition
Category: Uninterruptible Power Supplies (UPSs)
Prevent business interruptions and safeguard mission-critical enterprise network equipment.
The CyberPower OL1000RTXL2UN is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode.
The OL1000RTXL2UN offers generator compatibility and delivers clean AC power with zero transfer time. A factory installed RM card allows remote management and configuration of the UPS via a standard web browser, command line interface (CLI), or network management system (NMS). Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output.
With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
Double-Conversion Topology
Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. With the conversion to DC power, the UPS has a zero millisecond transfer time to battery power when utility power is lost. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
PowerPanel® Business Edition Software
Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205
Is a full-featured network management card. It enables remote management of up to 50 clients via a standard web browser, command line interface (CLI), or network management system (NMS) connection.
LCD Control Panel
Displays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.
Extended Battery Module (EBM)
Extends runtime by adding up to 10 EBMs.
Fast Charge Technology
Allows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores a complete charge within 4 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO Mode
Improves UPS efficiency up to 94% reducing electrical and cooling costs.
Hot-Swappable Batteries
Keep equipment running by eliminating downtime during UPS battery replacement.
Upgradeable UPS firmware
Manages the unit’s features and functions.
Critical & Non-Critical Load Banks
Maximize the output of the UPS by setting non-critical loads to shut off allowing additional runtime for critical load outlets.
Emergency Power Off (EPO)
Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Generator Compatible
Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity
Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Data Line Surge Protection
Prevents power surges that traveling through telephone and Ethernet lines from causing damage to your equipment
Audible Alarms
Identify when the model is running on battery power, overloaded, or has a low battery.
Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights
Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
The CyberPower OL1000RTXL2UN is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode.
The OL1000RTXL2UN offers generator compatibility and delivers clean AC power with zero transfer time. A factory installed RM card allows remote management and configuration of the UPS via a standard web browser, command line interface (CLI), or network management system (NMS). Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output.
With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
Double-Conversion Topology
Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. With the conversion to DC power, the UPS has a zero millisecond transfer time to battery power when utility power is lost. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
PowerPanel® Business Edition Software
Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205
Is a full-featured network management card. It enables remote management of up to 50 clients via a standard web browser, command line interface (CLI), or network management system (NMS) connection.
LCD Control Panel
Displays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.
Extended Battery Module (EBM)
Extends runtime by adding up to 10 EBMs.
Fast Charge Technology
Allows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores a complete charge within 4 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO Mode
Improves UPS efficiency up to 94% reducing electrical and cooling costs.
Hot-Swappable Batteries
Keep equipment running by eliminating downtime during UPS battery replacement.
Upgradeable UPS firmware
Manages the unit’s features and functions.
Critical & Non-Critical Load Banks
Maximize the output of the UPS by setting non-critical loads to shut off allowing additional runtime for critical load outlets.
Emergency Power Off (EPO)
Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Generator Compatible
Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity
Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Data Line Surge Protection
Prevents power surges that traveling through telephone and Ethernet lines from causing damage to your equipment
Audible Alarms
Identify when the model is running on battery power, overloaded, or has a low battery.
Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights
Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
| Power | |
|---|---|
| Output power capacity | 1 kVA |
| Output power | 900 W |
| Input operation voltage (min) | 60 V |
| Input operation voltage (max) | 150 V |
| Output operation voltage (min) | 100 V |
| Output operation voltage (max) | 125 V |
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Output power factor | 0.9 |
| Output frequency regulation | 0.25 Hz |
| Output frequency | 50/60 Hz |
| Input power factor | 0.99 |
| Crest factor | 3:1 |
| Efficiency (ECO mode) | 94% |
| ECO mode | Yes |
| Input frequency | 40/70 Hz |
| Ports & interfaces | |
| Cable length | 118.1" (3 m) |
| AC outlets quantity | 8 AC outlet(s) |
| AC outlet types | NEMA 5–15R |
| Power plug | NEMA 5-15P |
| Emergency Power Off (EPO) connector | Yes |
| USB port | Yes |
| Serial ports quantity | 1 |
| Modem (RJ-11) ports | 1 |
| Ethernet LAN (RJ-45) ports | 1 |
| Performance | |
| UPS topology | Double-conversion (Online) |
| Audible alarm modes | Fault, Low battery alarm, Overload alarm |
| EMI/RFI noise filtering | Yes |
| Surge protection | Yes |
| Surge protection features | Network, Telephone |
| Waveform | Sine |
| LED indicators | Yes |
| Audible alarm(s) | Yes |
| Features | |
| UPS topology | Double-conversion (Online) |
| Output power capacity | 1 kVA |
| Audible alarm modes | Fault, Low battery alarm, Overload alarm |
| Output power | 900 W |
| Input operation voltage (min) | 60 V |
| Input operation voltage (max) | 150 V |
| Output operation voltage (min) | 100 V |
| Output operation voltage (max) | 125 V |
| EMI/RFI noise filtering | Yes |
| Surge protection | Yes |
| Surge protection features | Network, Telephone |
| Waveform | Sine |
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Output power factor | 0.9 |
| Output frequency regulation | 0.25 Hz |
| Output frequency | 50/60 Hz |
| Input power factor | 0.99 |
| Crest factor | 3:1 |
| Audible alarm(s) | Yes |
| Efficiency (ECO mode) | 94% |
| ECO mode | Yes |
| Input frequency | 40/70 Hz |
| Battery | |
| Number of battery cells | 3 |
| Battery recharge time | 4 h |
| Typical backup time at half load | 20 min |
| Typical backup time at full load | 7.4 min |
| Hot-swap battery | Yes |
| Cold start | Yes |
| Battery voltage | 12 V |
| Battery capacity | 9 Ah |
| Replacement battery cartridge | RB1290X3L |
| Design | |
| Form factor | Rackmount/Tower |
| Rack capacity | 2U |
| Product colour | Black |
| Safety | UL 1778 5th Ed.CSA C22.2 NO.107.3-05FCC Part 15 Class A CSA C22.2 NO.107.3-05 FCC Part 15 Class B |
| Cable length | 118.1" (3 m) |
| LED indicators | Yes |
| Housing material | Steel |
| Display type | LCD |
| Operational conditions | |
|---|---|
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -20 - 45 °C |
| Operating relative humidity (H-H) | 0 - 90% |
| Storage relative humidity (H-H) | 0 - 95% |
| Technical details | |
| Output frequency | 50/60 Hz |
| Compliance certificates | RoHS |
| Weight & dimensions | |
| Width | 17" (432 mm) |
| Depth | 16.9" (429 mm) |
| Height | 3.46" (88 mm) |
| Weight | 39.7 lbs (18 kg) |
| Package width | 21.5" (546.1 mm) |
| Package depth | 22.5" (571.5 mm) |
| Package height | 9.27" (235.5 mm) |
| Package weight | 0.856 oz (24.3 g) |
| Packaging data | |
| Cables included | Phone (RJ-11), Serial, USB cable |
| Rack mount kit | Yes |
| Manual | Yes |
| Package width | 21.5" (546.1 mm) |
| Package depth | 22.5" (571.5 mm) |
| Package height | 9.27" (235.5 mm) |
| Package weight | 0.856 oz (24.3 g) |
| Certificates | |
| Safety | UL 1778 5th Ed.CSA C22.2 NO.107.3-05FCC Part 15 Class A CSA C22.2 NO.107.3-05 FCC Part 15 Class B |
| Packaging content | |
| Cables included | Phone (RJ-11), Serial, USB cable |
| Rack mount kit | Yes |
| Manual | Yes |
You may also be interested in
| Product |
Recommended
CyberPower OL1000RTXL2UN uninterruptib...
Login for pricing
|
Eaton 5PX G2 UPS uninterruptible power...
Login for pricing
|
Bestseller
Eaton 9PX 1500RT uninterruptible power...
Login for pricing
|
Hot Product
CyberPower OL1500RTXL2UN uninterruptib...
Login for pricing
|
APC SRT1500XLA uninterruptible power s...
Login for pricing
|
Popular
Tripp Lite SMART1500RM2UN uninterrupti...
Login for pricing
|
|---|---|---|---|---|---|---|
| SKU |
OL1000RTXL2UN
|
5PX1500RTG2
|
9PX1500RT
|
OL1500RTXL2UN
|
SRT1500XLA
|
SMART1500RM2UN
|
| Manufacturer |
CyberPower
|
Eaton
|
Eaton
|
CyberPower
|
APC
|
Tripp Lite
|
| Form factor |
Rackmount/Tower
|
Rackmount/Tower
|
Rackmount/Tower
|
Rackmount/Tower
|
Mini tower
|
Rackmount/Tower
|
| Output power capacity |
600VA to 1200VA
|
N/A
|
1200VA to 4000VA
|
1200VA to 4000VA
|
8000VA to 16000VA
|
1200VA to 4000VA
|
| Product colour |
Black
|
N/A
|
Black
|
Black
|
Black
|
Black
|
| Output power |
500W to 1000W
|
1000W to 1500W
|
1000W to 1500W
|
1000W to 1500W
|
1000W to 1500W
|
1000W to 1500W
|
| UPS topology |
Double-conversion (Online)
|
Line-Interactive
|
Double-conversion (Online)
|
Double-conversion (Online)
|
Double-conversion (Online)
|
Line-Interactive
|